250+ TOP MCQs on Effect of Various Parameters on VCR System – 1 and Answers

Refrigeration Multiple Choice Questions on “Effect of Various Parameters on VCR System – 1”.

Sodium citrate, citrate, sodium citrate, sodium citrate, citric, citric-acid, citrate, citric, citric-acid, citrate. Topical tamoxifen rybelsus coupon without insurance is a non-hormonal medication, a synthetic hormone antagonist which reduces the activity of the estrogen receptors, which normally stimulate cells to grow and divide. Nolvadex is also helpful to lose the fat from my thighs and i am able to maintain the weight i am carrying, the problem that i have is i want to take more nolvadex than recommended, my doctor is not sure about it and wants me to do some blood tests to find out the amount of nolvadex i take, i am not going to have any problem taking this, i have been taking this since i was 19, but since the first time i took it i got the headache and nausea feeling and my energy level is down.

1. Which of these is not an effect of superheat in suction vapour?
a) increase in refrigeration effect
b) increase in compression work
c) decrease the capacity of compressor per ton of refrigeration
d) condenser size decreases
Answer: d
Clarification: The effects of superheat in suction vapour are increase in refrigeration effect, increase in compression work, decreasing the capacity of compressor per ton of refrigeration and increasing the condenser size as the heat rejected in the condenser increases.

2. The COP of the cycle may increase or decrease or remain unchanged depending upon the range of pressure and the degree of superheating.
a) True
b) False
Answer: a
Clarification: The COP of the cycle may increase or decrease or remain unchanged depending upon the range of pressure and the degree of superheating as it can affect the refrigeration effect, compression work, heat rejected in condenser etc. and thus the COP.

3. In which case will the refrigeration effect will not increase and the COP of cycle with superheated vapour in suction phase will be less than the COP of ideal cycle?
a) Superheating the vapour from state 1 to 1′
b) Superheating the vapour from state 1 to 2
c) Superheating the vapour from state 1′ to 2′
d) COP always increases when superheating vapour in suction vapour
Answer: a
Clarification: As we can see from the below picture of a cycle with superheated vapour in suction vapour, the refrigeration effect is not increased and thus the COP will be less than that of ideal COP.
refrigeration-questions-answers-effect-various-parameters-vcr-system-1-q3

4. Which one of the following is not effect of liquid sub cooling?
a) increase the refrigeration effect
b) reduce the piston displacement
c) increase the COP
d) increase the compressor power per ton of refrigeration
Answer: d
Clarification: Sub cooling the liquid reduces the compressor power per ton of refrigeration due to reduced mass flow rate of refrigerant. It also increases the refrigeration effect, reduce the piston displacement and increase the COP.

5. Which one of the following is not effect of change in suction pressure?
a) reduces the net refrigeration effect
b) reduces the mass flow rate of refrigerant per ton of refrigeration
c) reduces the COP
d) increases the compressor power per ton of refrigeration
Answer: b
Clarification: Change in suction pressure reduces the net refrigeration effect thus increasing the mass flow rate of refrigerant per ton of refrigeration.

6. Effect of high side pressure or discharge pressure or condenser pressure is to reduce the COP of the cycle.
a) True
b) False
Answer: a
Clarification: Effect of high side pressure or discharge pressure or condenser pressure is to reduce the COP of the cycle as the refrigeration effect is reduced and the compression work increases as well as the compressor power increases per ton of refrigeration due to increased mass flow and additional energy supplied in compression.

7. Heat rejected in the condenser increases by an amount equal to, when vapour in the suction vapour is superheated?
refrigeration-questions-answers-effect-various-parameters-vcr-system-1-q3
a) H2 – H2′
b) H2 + H2′
c) H2′ – H2
d) H2′ + H2
Answer: c
Clarification: As we see from the below diagram the heat rejected in the condenser increases by an amount equal to H2′ – H2.
refrigeration-questions-answers-effect-various-parameters-vcr-system-1-q3