MCB is the acronym used for the miniature circuit breaker and is commonly used in our day to day lives. Its primary function is to break the circuit when the current flowing through the circuit reaches past a certain set limit. In conditions such as short circuit or overload, these devices trip by themselves hence saving the house by the damages caused by a short circuit or overload or as the case may be. The mechanism of MCB has 3 possible positions, ‘ON’, ‘OFF’, and ‘TRIPPED’, hence the breaker provides manual means of opening and closing of the circuit. MCB is a kind of a better version of a fuse.
MCB Symbol
MCB Electrical
MCBs work on a time-delay tripping mechanism. This means that they function whenever there is an overload or higher flow of current for a longer duration of time, the duration which can hamper the normal functioning of the circuit. The time duration if exceeds a certain value the MCB trips and breaks the circuit thus rendering the overload dysfunctional in damaging the appliances and further circuit.
What is MCCB?
MCCB is the short form for a moulded case circuit breaker. It is used to protect the electric circuit from the flowing of excessive current which can further cause damages such as overload and short circuit. They are being used for a wide range of frequencies with the current rating up to 2500A and adjustable trip settings. MCCB provides overload protection via the temperature-sensitive component. These are usually used in PV systems in place of miniature circuit breakers. These work on principles of electromagnetism and cam also be disconnected manually. MCCB’s are subjected to high current, therefore they need proper maintenance and can be maintained by regular cleaning, lubricating, and testing.
How is MCCB different from MCB?
MCB’s trip characteristics may not be adjusted since they are mostly provided to low circuits with the MCB rated 100 amps with an interrupting rating of under 18000 amps. Whereas MCCB has the characteristics of the adjustable trip which is used in higher models. MCCBs provide amps between 2500-10 and their interrupting rating ranges from 10,000 amps to 200,00 amps. Hence this states that MCB is usually used for low energy requirements such as home wiring or small electric circuits, on the other hand, MCCB is more suited for high energy requirements.
MCB being rated under 100 amps doesn’t come with the feature of the adjustable trip, hence they always cater low current circuit. Whereas MCCBs being rated from 10 to 2500 amps comes with an adjustable trip feature so they can cater for high current circuits
Although an MCCB possesses a higher capacity than an MCB, both are classified under low voltage circuit breakers and should respond to standards set by the IEC 947. For the sake of convenience, MCCB is equipped with a special feature of being tripped only by remote as their units have electrical motor operators. Whereas MCB lacks this feature.
MCCB is said to be more suited for higher energy due to the possession of better capacity than MCB, whereas MCB is usually provided for low energy requirements, hence they are best suited for them.
Obviously, when it comes to home use or some light work, the MCB is better preferred due to low energy requirements. On the other hand, when it comes to industrial use or any other heavy-duty requirements, MCCB is the best suited.
Difference Between MCB and MCCB.
Basis of Comparison |
MCB |
MCCB |
Definition |
Type of electrical switch which protects the circuit from overload or short circuit. |
Type of device which protects the equipment from over-temperature and fault current. |
Abbreviation |
Miniature Circuit Breaker |
Molded Case Circuit Breaker |
Tripping Circuit |
Fixed |
Movable |
Pole |
Available in single, two, three, and four versions. |
Available in single, two, three, and four versions. |
Rating Current |
100 amps |
10 – 200 amps |
Interrupting Rating |
1800 amps |
10k-200k amps |
Remote on/off |
Not possible |
Possible |
Applications |
In low current circuits |
In heavy current circuits |
Use |
For domestic use. |
For commercial and industrial use. |
Did You Know?!
The miniature circuit breaker was invented by Stotz-Kontakt, a company that was established in Mannheim, Germany, in the year 1891.