Waste Water Engineering Assessment Questions and Answers on “Phosphorus Removal – 2”.
1. What is the retention time considered for the anaerobic zone for the AO process for removing phosphorus?
a) 0.5-1.5 hrs
b) 1.5-2 hrs
c) 2-4 hrs
d) 4-8 hrs
Answer: a
Clarification: The retention time considered for the anaerobic zone for the AO process for removing phosphorus is 0.5-1.5 hrs. This process involves aerobic oxidation followed by anaerobic digestion. This is a very effective method to remove phosphorus compounds.
2. What is the retention time considered for the aerobic zone for the AO process for removing phosphorus?
a) 1-3 hrs
b) 3-5 hrs
c) 5-8 hrs
d) 8-11 hrs
Answer: a
Clarification: The retention time considered for the aerobic zone for the AO process for removing phosphorus is 1-3 hrs. This process involves aerobic oxidation followed by anaerobic digestion. This is a very effective method to remove phosphorus compounds.
3. What is the retention time considered for the anaerobic zone for the A2O process for removing phosphorus?
a) 0.5-1.5 hrs
b) 1.5-2 hrs
c) 5-7 hrs
d) 3-4 hrs
Answer: a
Clarification: The retention time considered for the anaerobic zone for the A2O process for removing phosphorus is 0.5-1.5 hrs. This process is a modification process of the AO process. This is a very effective method to remove phosphorus compounds.
4. What is the retention time considered for the aerobic zone for the A2O process for removing phosphorus?
a) 0.5-1.5 hrs
b) 1.5-3 hrs
c) 3-4 hrs
d) 4-8 hrs
Answer: d
Clarification: The retention time considered for the aerobic zone for the A2O process for removing phosphorus is 4-8 hrs. This process is a modification process of the AO process. This is a very effective method to remove phosphorus compounds.
5. What is the retention time considered for the anoxic zone for the A2O process for removing phosphorus?
a) 0.5-1 hrs
b) 1-2 hrs
c) 2-4 hrs
d) 4-6 hrs
Answer: a
Clarification: The retention time considered for the anoxic zone for the A2O process for removing phosphorus is 0.5-1 hrs. This process is a modification process of the AO process. This is a very effective method to remove phosphorus compounds.
6. What is the retention time considered for the anoxic zone for the University of Cape Town treatment process for removing phosphorus?
a) 2-4 hrs
b) 4-6 hrs
c) 6-8 hrs
d) 8-10 hrs
Answer: a
Clarification: The retention time considered for the anoxic zone for the University of Cape Town treatment process for removing phosphorus is 2-4 hrs. The MLSS level maintained is 3000-4000 mg/L. The internal recirculation considered is 200-400%.
7. What is the retention time considered for the anaerobic zone for the University of Cape Town treatment process for removing phosphorus?
a) 1-2 hrs
b) 3-4 hrs
c) 4-8 hrs
d) 8-12 hrs
Answer: a
Clarification: The retention time considered for the anaerobic zone for the University of Cape Town treatment process for removing phosphorus is 1-2 hrs. The MLSS level maintained is 3000-4000 mg/L. The internal recirculation considered is 200-400%.
8. What is the retention time considered for the aerobic zone for the University of Cape Town treatment process for removing phosphorus?
a) 4-12 hrs
b) 3-4 hrs
c) 1-2 hrs
d) 5-6 hrs
Answer: a
Clarification: The retention time considered for the aerobic zone for the University of Cape Town treatment process for removing phosphorus is 4-12 hrs. The MLSS level maintained is 3000-4000 mg/L. The internal recirculation considered is 200-400%.
9. What is the retention time considered for the aerobic zone for the Virginia Initiative Plant treatment process for removing phosphorus?
a) 4-6 hrs
b) 10-12 hrs
c) 2-4 hrs
d) 1-2 hrs
Answer: a
Clarification: The retention time considered for the aerobic zone for the Virginia Initiative Plant treatment process for removing phosphorus is 4-6 hrs. The MLSS level maintained is 2000-4000 mg/L. The internal recirculation considered is 100-200% for the anoxic tank.
10. What is the retention time considered for the aerobic zone for the Virginia Initiative Plant treatment process for removing phosphorus?
a) 3-5 hrs
b) 7-9 hrs
c) 1-2 hrs
d) 4-6 hrs
Answer: c
Clarification: The retention time considered for the anaerobic zone for the Virginia Initiative Plant treatment process for removing phosphorus is 1-2 hrs. The MLSS level maintained is 2000-4000 mg/L. The internal recirculation considered is 100-200% for the anoxic tank.
Waste Water Engineering Assessment Questions,