250+ TOP MCQs on Phosphorus Removal – 2 and Answers

Waste Water Engineering Assessment Questions and Answers on “Phosphorus Removal – 2”.

1. What is the retention time considered for the anaerobic zone for the AO process for removing phosphorus?
a) 0.5-1.5 hrs
b) 1.5-2 hrs
c) 2-4 hrs
d) 4-8 hrs
Answer: a
Clarification: The retention time considered for the anaerobic zone for the AO process for removing phosphorus is 0.5-1.5 hrs. This process involves aerobic oxidation followed by anaerobic digestion. This is a very effective method to remove phosphorus compounds.

2. What is the retention time considered for the aerobic zone for the AO process for removing phosphorus?
a) 1-3 hrs
b) 3-5 hrs
c) 5-8 hrs
d) 8-11 hrs
Answer: a
Clarification: The retention time considered for the aerobic zone for the AO process for removing phosphorus is 1-3 hrs. This process involves aerobic oxidation followed by anaerobic digestion. This is a very effective method to remove phosphorus compounds.

3. What is the retention time considered for the anaerobic zone for the A2O process for removing phosphorus?
a) 0.5-1.5 hrs
b) 1.5-2 hrs
c) 5-7 hrs
d) 3-4 hrs
Answer: a
Clarification: The retention time considered for the anaerobic zone for the A2O process for removing phosphorus is 0.5-1.5 hrs. This process is a modification process of the AO process. This is a very effective method to remove phosphorus compounds.

4. What is the retention time considered for the aerobic zone for the A2O process for removing phosphorus?
a) 0.5-1.5 hrs
b) 1.5-3 hrs
c) 3-4 hrs
d) 4-8 hrs
Answer: d
Clarification: The retention time considered for the aerobic zone for the A2O process for removing phosphorus is 4-8 hrs. This process is a modification process of the AO process. This is a very effective method to remove phosphorus compounds.

  250+ TOP MCQs on Diffused and Mechanical Aeration Systems and Answers

5. What is the retention time considered for the anoxic zone for the A2O process for removing phosphorus?
a) 0.5-1 hrs
b) 1-2 hrs
c) 2-4 hrs
d) 4-6 hrs
Answer: a
Clarification: The retention time considered for the anoxic zone for the A2O process for removing phosphorus is 0.5-1 hrs. This process is a modification process of the AO process. This is a very effective method to remove phosphorus compounds.

6. What is the retention time considered for the anoxic zone for the University of Cape Town treatment process for removing phosphorus?
a) 2-4 hrs
b) 4-6 hrs
c) 6-8 hrs
d) 8-10 hrs
Answer: a
Clarification: The retention time considered for the anoxic zone for the University of Cape Town treatment process for removing phosphorus is 2-4 hrs. The MLSS level maintained is 3000-4000 mg/L. The internal recirculation considered is 200-400%.

7. What is the retention time considered for the anaerobic zone for the University of Cape Town treatment process for removing phosphorus?
a) 1-2 hrs
b) 3-4 hrs
c) 4-8 hrs
d) 8-12 hrs
Answer: a
Clarification: The retention time considered for the anaerobic zone for the University of Cape Town treatment process for removing phosphorus is 1-2 hrs. The MLSS level maintained is 3000-4000 mg/L. The internal recirculation considered is 200-400%.

8. What is the retention time considered for the aerobic zone for the University of Cape Town treatment process for removing phosphorus?
a) 4-12 hrs
b) 3-4 hrs
c) 1-2 hrs
d) 5-6 hrs
Answer: a
Clarification: The retention time considered for the aerobic zone for the University of Cape Town treatment process for removing phosphorus is 4-12 hrs. The MLSS level maintained is 3000-4000 mg/L. The internal recirculation considered is 200-400%.

  250+ TOP MCQs on Settling of Discrete Particles and Answers

9. What is the retention time considered for the aerobic zone for the Virginia Initiative Plant treatment process for removing phosphorus?
a) 4-6 hrs
b) 10-12 hrs
c) 2-4 hrs
d) 1-2 hrs
Answer: a
Clarification: The retention time considered for the aerobic zone for the Virginia Initiative Plant treatment process for removing phosphorus is 4-6 hrs. The MLSS level maintained is 2000-4000 mg/L. The internal recirculation considered is 100-200% for the anoxic tank.

10. What is the retention time considered for the aerobic zone for the Virginia Initiative Plant treatment process for removing phosphorus?
a) 3-5 hrs
b) 7-9 hrs
c) 1-2 hrs
d) 4-6 hrs
Answer: c
Clarification: The retention time considered for the anaerobic zone for the Virginia Initiative Plant treatment process for removing phosphorus is 1-2 hrs. The MLSS level maintained is 2000-4000 mg/L. The internal recirculation considered is 100-200% for the anoxic tank.

Waste Water Engineering Assessment Questions,

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top