Statistical Quality Control Multiple Choice Questions on “Control Charting Techniques – Statistical Process Control for Short Production Runs – 1”.
1. Which of these is the correct expansion of DNOM?
a) Deviation from Lognormal
b) Derived from normal
c) Deviation from normal
d) Deviation from normality
Answer: c
Clarification: The DNOM in DNOM control chart denote the deviation from normal. This technique is used for the process quality control in the case of short process run or production runs.
2. Which of these is used as a technique for process control for short production runs?
a) Using deviation from nominal to plot the control chart
b) Using the variable value to plot the control chart
c) Using the variable change to plot the control chart
d) Using the variable decrease or increase to plot the chart
Answer: a
Clarification: The short production runs are having very wide applications in modern industries. The statistical process control technique used for the short production runs is generally measuring deviation from nominal value to plot the control chart, instead of the variable control chart.
3. If the Mi is the actual sample measurement, and TA is a nominal value, what will be the DNOM?
a) xi = Mi – 2TA
b) xi = Mi – TA
c) xi = 2TA – Mi
d) xi = TA + Mi
Answer: b
Clarification: The deviation from the normal or nominal value (DNOM) is used for the plotting of DNOM control chart. The deviation from the normal is evaluated as,
xi = Mi – TA.
4. The mean of the variable measured is replaced by the mean of ________ value in the case of the DNOM chart.
a) Normal value
b) Deviation from normal
c) Range
d) Deviation from normal range
Answer: b
Clarification: The DNOM chart is used for short production runs, which used DNOM or deviation from normal as the xas in the case of x chart. SO the mean of variable measured is replaced by the mean of the DNOM values.
5. If in a manufacturing process, the measurements for a certain dimension for a part are, 50, 51 and 52; where the nominal value of the dimension measured is 50, what will be the DNOM mean?
a) 1.0
b) 50
c) 51
d) 0.33
Answer: a
Clarification: We know that the deviations from nominal are,
xi = Mi – TA
By putting values, we get DNOM’s 0, 1 and 2. The mean DNOM will be 1.0.
6. How many samples are generally taken before calculating the control limits for the DNOM x bar and R charts?
a) 10
b) 40
c) 35
d) 20
Answer: d
Clarification: We use the DNOM mean for the plot of the x bar and R charts using the deviation from the normal. It is recommended that we should take almost 20 samples before calculating the control limits for DNOM x bar and R chart.
7. Which of these assumptions are made while using the DNOM approach?
a) The process standard deviation is same for all parts
b) The process standard deviation is different for all parts
c) The samples size is variable
d) The sample size is 1
Answer: a
Clarification: DNOM approach is defined as the method to plot control charts by calculating the deviation from the nominal value. While using this approach, it is assumed that, the process standard deviation is same for all parts.
8. Which of these is true for DNOM approach?
a) The sample size is variable
b) The process standard deviation is different for all parts
c) The sample size varies from one part to another
d) The sample size remains same for all parts