250+ TOP MCQs on Starting of Polyphase Induction Motors-I and Answers

Electrical Machines Multiple Choice Questions on “Starting of Polyphase Induction Motors”.

1. Voltage induce in the induction motor is highest at __________
A. starting
B. standstill
C. rated speed
D. any of the mentioned
Answer: A
Clarification: At starting when slip is 1, the voltage induced is maximum.

2. Starters are required in the induction motor because __________
A. of high starting current
B. they are not self starting
C. torque produced is very low at starting to overcome inertia
D. all of the mentioned
Answer: A
Clarification: Starters are needed in induction motors to limit the starting current.

3. Full voltage starting of induction motor may cause __________
A. dip in the voltages
B. high inrush current
C. high losses
D. all of the mentioned
Answer: A
Clarification: Starting induction motor on full load will cause high inrush current which furthe causes dip in the bus voltage.

4. For a 4-pole, 50 Hz induction motor has starting current as 5 times to that of the full load current working at a speed of 1450rpm. The ratio of starting to full load torque will be?
A. 0.83
B. 0.17
C. 0.67
D. 1
Answer: A
Clarification: Tst/Tfl = (Ist/Ifl)^2*slip
Tst/Tfl = 25*0.033
= 0.83

5. Starting methods applicable to both squirrel-cage and slip ring induction motors is/are __________

A. DOL starting
B. Auto transformer starting
C. Rotor resistance starting

A. A, B
B. A, B, C
C. B, C
D. A, C
Answer: A
Clarification: Rotor resistance method can only be used with slip ring induction motor.

6. The method which employs reduction of the voltage while induction motor starting is?

A. DOL starting
B. Auto transformer starting

A. Only A
B. A, B
C. Only B
D. Neither A nor B
Answer: A
Clarification: Direct online starting uses reduction in voltage.

7. The method which employs raising of the voltage while induction motor starting is?

A. DOL starting
B. Auto transformer starting

A. Only A
B. A, B
C. Only B
D. Neither A nor B
Answer: D
Clarification: None of the starting methods use increase in the starting voltage.

8. External methods of induction motor starting is employed to __________
A. Reduce the voltage
B. Reduce the current
C. Improve efficiency
D. All of the mentioned
Answer: A
Clarification: External methods like auto transformer is used to mainly reduce voltage.

9. A 3-phase, 4-pole, 50 Hz induction motor is uses DOL method of starting. It is later replaced by reactance method of starting with a fraction of ‘x’, then the starting current reduces by?
A. x
B. x^2
C. 1/x
D. no change in the starting current
Answer: A
Clarification: The current will be reduced by a fraction of x.

10. A 3-phase, 4-pole, 50 Hz induction motor is uses DOL method of starting. It is later replaced by reactance method of starting with a fraction of ‘x’, then the starting torque reduces by?
A. x
B. x^2
C. 1/x
D. no change in the starting current
Answer: B
Clarification: Tst/Tfl = (x^2)(Ist/Ifl)^2*slip.

11. Series reactor method of starting has main disadvantage of __________
A. lowering the starting power
B. increasing the starting current
C. increasing starting torque
D. all of the mentioned
Answer: A
Clarification: Main disadvantage of using reactors is that ot reduces the starting power of the machine and so the efficiency.

12. Series reactor method of starting has main disadvantage of lowering the starting power. This can be overcome by __________
A. using series resistance
B. using parallel reactor
C. using parallel resistance
D. using series reactor
Answer: A
Clarification: Adding series resistance instead od reactors will help improving the starting power.

13. A 3-phase, 4-pole, 50 Hz induction motor is uses DOL method of starting. It is later replaced by auto transformer method of starting with a tapping ratio of ‘x’, then the starting current reduces by?
A. x
B. x^2
C. 1/x
D. no change in the starting current
Answer: B
Clarification: The starting current reduces by a fraction of x^2.

14. A 3-phase, 4-pole, 50 Hz induction motor is uses DOL method of starting. It is later replaced by auto transformer method of starting with a tapping ratio of ‘x’, then the starting torque will be?
A. x *Tfl
B. x^2 *Tfl
C. 1/x *Tfl
D. no change in the starting current
Answer: A
Clarification: Tst/Tfl = (x^2)(Ist/Ifl)^2*slip.

15. For the application requiring high starting torque and minimum starting current, the most suitable starting method will be?
A. Auto transformer starting method
B. Reactance starting method
C. DOL method
D. Star-Delta method
Answer: A
Clarification: Auto transformer provides the maximum starting torque.

16. Auto transformer method of starting has most acceptable method for the starting of the induction motor due to __________
A. maximum torque
B. maximum reduction of inrush current
C. variable tapping
D. all of he mentioned
Answer: A