Waste Water Engineering Multiple Choice Questions on “Pipes and Traps”.
1. What is the device used to prevent sewer gases from entering the buildings?
a) Filters
b) Traps
c) Ventilators
d) Vacuum pumps
Answer: b
Clarification: A trap is a device which is used to prevent sewer gases from entering the buildings. The traps retain the small amount of water and are located below or within a plumbing fixture.
2. The traps should be of self cleansing pattern.
a) True
b) False
Answer: a
Clarification: The traps must self-cleanse and remain clean. Good traps must contain efficient water seal under all conditions of flow.
3. The European WC contains attached trap.
a) True
b) False
Answer: b
Clarification: Trap may be manufactured as an integral trap within the appliance as in some models of European WC or there may be separate trap connected to waste or foul water outlet of appliances.
4. _________ is constructed outside the building to carry wastewater discharge.
a) Gully trap
b) P. trap
c) S. trap
d) Floor trap
Answer: a
Clarification: Gully traps are constructed outside the building to carry waste water discharge from washbasin, sinks, bathroom etc.
5. What is the minimum depth of water required in gully trap?
a) 10 mm
b) 20 mm
c) 40 mm
d) 50 mm
Answer: d
Clarification: Gully traps are deep seal traps, the depth of water seal should be 50 mm minimum. It prevents the entry of insects from sewer line to waste pipes carrying wastewater.
6. Indian water closet generally uses ______
a) P. trap
b) Gully trap
c) Bottle trap
d) Grease trap
Answer: a
Clarification: Indian water closet generally uses P. trap and they are made from cast iron or UPV sheet. It also prevents the entry of gases by water seal.
7. What is P. trap made of?
a) Polymer
b) Cast iron
c) Wrought iron
d) Plastic
Answer: b
Clarification: P. traps are made from cast iron or UPV sheet. P. traps are usually used in the Indian water closets.
8. _________ is similar to P. trap.
a) Floor trap
b) S. trap
c) Intercepting trap
d) Q trap
Answer: b
Clarification: S. trap is similar to P. trap and is used for fixing water closets in toilets. The only difference between P. trap and S. trap is that P. trap is used for walls containing outlets whereas S. trap is used for floor containing outlets.
9. ______ is provided on the floor to collect wastewater from various sources like sinks.
a) Nahini trap
b) Intercepting trap
c) S. trap
d) P. trap
Answer: a
Clarification: Nahini trap or floor trap is provided in the floor to collect waste water from washbasin, shower, sink and bathroom etc.
10. What is the minimum depth of water seal in floor trap?
a) 25 mm
b) 50 mm
c) 75 mm
d) 100 mm
Answer: b
Clarification: The floor traps are available in cast iron or UPVC material and have removable grating (JALI) on the top of the trap and minimum water depths should be 50 mm.
11. At the last main hole of building sewerage, __________ is provided.
a) Grease trap
b) Gully trap
c) Intercepting trap
d) Nahini trap