Tough Statistical Quality Control Questions and Answers on “Control Charting Techniques – Statistical Process Control for Short Production Runs – 4”.
1. EWMA and cusum charts can be used for the short production runs because ____________
a) They are good in phase II
b) They have shorter ARL
c) They don’t detect process shift
d) They detect larger process shift
Answer: b
Clarification: EWMA charts and the cusum charts both, find applications in the short production run cases. This is due to the fact that the EWMA charts and the Cusum charts both have shorter ARL than the Shewhart charts.
2. Which of these is suitable for the short run environment?
a) x bar chart
b) R chart
c) p-chart
d) Self starting cusum chart
Answer: d
Clarification: The Cusum charts are effective for subgroups size of one. The self starting version of the Cusum charts is particularly suitable for the short run environment due to the same fact.
3. Which of these is not one of the areas for which, the self starting cusum approach uses regular process measurements for?
a) For establishing the cusum
b) For calibrating the cusum
c) For acceptance sampling
d) For process monitoring
Answer: c
Clarification: The self starting approach of cusum charts uses regular process measurements for both establishing the cusum, and calibrating of cusum. These measurements are also used for process monitoring.
4. Which of these is eliminated by the self starting approach?
a) Phase I parameter estimation phase
b) Phase I parameter measurement phase
c) Phase II parameter estimation phase
d) Phase II parameter measurement phase
Answer: a
Clarification: The self starting approach uses regular process measurements for establishing and calibrating the cusum, and for process monitoring. Thus, this eliminates the phase I parameter estimation stage.
5. The false alarm rate is _______ when small number of subgroups is used for the Shewhart control charts.
a) Decreased
b) Increased
c) Remains same
d) Changed randomly
Answer: b
Clarification: The number of subgroups used in calculating the trial control limits for Shewhart control charts, impacts the false alarm rate of the chart. This rate is inflated when small number if subgroups is used.
6. Who was the first person to study the effect of the number of subgroups used for x bar and R chart control limit calculation on the false alarm rate?
a) Hillier
b) Robertson
c) Wang
d) Ricardo
Answer: a
Clarification: The false alarm rate of the Shewhart control charts also depends over the number of subgroups used to construct the trial control limits. This was first studied by Hillier (1969).
7. Which of these charts can be used instead of Shewhart control charts, in the case of small number of subgroups used to construct the charts, which were recommended by Quesenberry?
a) R-charts
b) C-charts
c) P-charts
d) Q-charts
Answer: d
Clarification: Quesenberry recommended the Q charts to be used in the place of the Shewhart control charts, in the case of small subgroup number used to calculate the control limits. This was because small number of subgroups used with Shewhart control charts, increased their FAR.
8. Which method was suggested by Del Castillo and Montgomery, to be used instead of the Q-chart to get better ARL performance?
a) Kalman Filter
b) Acceptance Sampling
c) Design of experiments
d) Deleting some samples completely