250+ TOP MCQs on TSDF – Air Quality Monitoring and Answers

Hazardous Waste Management Multiple Choice Questions on “TSDF – Air Quality Monitoring”.

1. Air quality monitoring stations should be _______ degree around TSDF.
a) 100
b) 110
c) 120
d) 130
Answer: c
Clarification: Air quality monitoring stations at upwind, downwind and at three stations at 120o angle around the TSDF is required.

2. The locations of air quality monitoring stations depends on _______
a) Stack height
b) Wind speed
c) Wind direction
d) Rainfall
Answer: a
Clarification: The locations of air quality monitoring stations depend on the stack height and location of any particular ecologically sensitive feature around the disposal facility.

3. Location of air quality monitoring stations is decided by PCB.
a) True
b) False
Answer: a
Clarification: Location of air quality monitoring stations is decided by Pollution Control Board (PCB) or Pollution Control Committee (PCC).

4. Total Volatile Organic Compounds has to be monitored apart from stipulated NAAQS.
a) True
b) False
Answer: a
Clarification: Total Volatile Organic Compounds (VOCs), Polycyclic Aromatic Hydrocarbons (PAH) has to be monitored apart from stipulated National Ambient Air Quality Standards (NAAQS) to minimized impacts from TSDF.

5. How many measurements should be taken for SPM in a year?
a) 100
b) 101
c) 102
d) 104
Answer: d
Clarification: SPM, RPM, NOx and SOxshould be continued to be monitored as per NAAQS criteria minimum of 104 measurements in a year taken twice a week, 24 hourly.

6. VOC should be monitored at least ______ a year.
a) Once
b) Twice
c) Thrice
d) Multiple

Answer: b
Clarification: Total Volatile Organic Compounds (VOCs), Polycyclic Aromatic Hydrocarbons (PAH) should be monitored at least twice in a year (pre-monsoon and post-monsoon).

7. Stack gaseous emission for the parameters should be carried out _______ basis.
a) Annual
b) Quarterly
c) Monthly
d) Hourly
Answer: b
Clarification: Quarterly monitoring of the stack gaseous emission for the parameters should be carried out as stipulated under the gaseous emission norms which is notified under the Environment (Protection) Fifth Amendment Rules, 2008.

8. Which of the following stack emission has to be monitored continuously?
a) HCL
b) C
c) O
d) PM
Answer: a
Clarification: SO2, NOx, HCL and CO stack emission has to be monitored continuously using on-line monitoring system.

9. Vent Gases attached with the capped SLF has to be monitored _______
a) Once a week
b) Once a month
c) Once a day
d) Once a year
Answer: b
Clarification: Vent Gases attached with the capped SLF such as total VOCs and H2S should be monitored at least once in a month through the vents of the capped cells till designed life span of the TSDF.

>

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top